Indoor air quality (IAQ) monitoring has long faced an interpretation challenge: continuous sensors produce high volumes of granular data, yet facility managers, sustainability teams, and office occupants often lack a common standard to determine what those readings mean in practice. To translate raw device outputs into clear operational benchmarks, Airthings—the Norwegian indoor air quality specialist—evaluated its own corporate headquarters in Oslo using the GO IAQS Standard (Version 1.2).
By benchmarking 23 of its commercial sensors against the GO IAQS “Ultimate” performance standard, Airthings demonstrated how an objective reporting standard bridges the gap between raw data collection and actionable facility management.
The Value of a Unified Standard
Modern offices generate continuous streams of IAQ metrics, but isolated numbers such as parts per million (ppm) or Becquerels per cubic meter (Bq/m3) can be difficult for non-technical stakeholders to interpret. The GO IAQS framework addresses this by standardizing evaluation across two key deliverables:
- The GO IAQS Report: A retrospective compliance audit that calculates the exact percentage of occupied hours a space maintains pollutant concentrations within target thresholds.
- The GO IAQS Score: An instantaneous snapshot rating spaces on an accessible grading scale, ranging from A (Good) to B (Moderate) and Z (Unhealthy), giving occupants and operators clear cues when to ventilate or reduce pollutant sources.
Rather than relying on vague environmental generalizations, Airthings utilized their Airthings MCP connector with the new GO IAQS tool to ingest sensor streams and assess performance hour by hour during occupied business hours (Monday through Friday, 07:00 to 17:00).
30-Day Performance: Airthings HQ Against GO IAQS Ultimate Limits
Covering 20 working days between September 26 and October 25, 2026, the GO IAQS Report analyzed 4,329 total device-hours across meeting rooms, collaboration hubs, open-plan workspaces, and shared zones. The assessment applied GO IAQS Ultimate limits across three target pollutants:
- Carbon Dioxide (CO2): ≤800 ppm
- Radon: ≤100 Bq/m3 (short-term rolling average)
- Particulate Matter (PM2.5): ≤15 μg/m3 (1-hour average)
Aggregate Building Compliance
| Pollutant | GO IAQS Ultimate Limit | Averaging Basis | Healthy Occupied Hours | Unhealthy Occupied Hours | Total Device-Hours Analyzed |
|---|---|---|---|---|---|
| PM2.5 | 15 μg/m3 | 1-hour average | 100.0% | 0.0% | 400 (monitored in 2 rooms) |
| Radon | 100 Bq/m3 | Instantaneous threshold | 98.6% | 1.4% (1.42%) | 3,528 |
| CO2 | 800 ppm | Instantaneous threshold | 96.7% | 3.3% (3.30%) | 4,329 |
Overall, no single room fell below 89.5% healthy occupied hours for any measured parameter over the entire 30-day reporting window.

Turning Data into Action: Room-by-Room Granularity
The primary operational benefit of the GO IAQS standard is isolating environmental issues down to specific rooms and root causes rather than masking problems behind whole-building averages.
Of the 23 spaces monitored, seven rooms achieved 100% compliance across all measured pollutants for every single occupied hour:
- Reception Area
- Lounge
- Software and Product Area
- Operations Area
- Software and Product Area – Space Radon
- Ozone
- B2B Area
The remaining 16 rooms exhibited isolated exceedances that pointed directly toward targeted interventions:
- Meeting Room Ventilation (CO2): Exceedances above the 800 ppm Ultimate threshold were concentrated in high-occupancy conference rooms during peak periods. Rooms such as 402 – Payment required (10.5% unhealthy hours; 89.5% healthy), 408 – Request timeout (9.1% unhealthy hours), and Radon (9.0% unhealthy hours) clearly signaled where HVAC airflow schedules or demand-controlled ventilation (DCV) setpoints required calibration.
- Radon Containment: In contrast to CO2, radon deviations were isolated to localized structural areas—most notably Hardware Area (8.5% unhealthy hours; 91.5% healthy) and 408 – Request timeout (9.1% unhealthy hours; 90.45% healthy).
Month-over-Month Progress: Radon Reduction
Comparing consecutive 30-day reporting windows demonstrated the clarity GO IAQS reporting brings to tracking mitigation and trends over time:
- Radon: Unhealthy occupied hours across the building dropped substantially from 6.5% (in the August 26 – September 24 period) to 1.4% (September 26 – October 25).
- Notable individual improvements occurred in rooms like 410 – Gone, where unhealthy radon hours dropped from 17.7% to 0%, as well as 204 – No Content (10.9% to 0%) and 307 – Temporary redirect (10.5% to 0%).
- CO2: Unhealthy hours remained steady, adjusting slightly from 3.6% down to 3.3%.
- PM2.5: Maintained 0.0% unhealthy hours across both consecutive periods.
While overall radon levels dropped building-wide, granular tracking identified that Hardware Area and 408 – Request timeout moved counter to the trend, highlighting exactly where facilities teams need to focus physical inspections.
Note: 402, 408, 307, 204, 410, and 413 are actual meeting room names.
Live Operational Awareness: The GO IAQS Score
Beyond historical compliance reports, Airthings tested live operational scoring. On the morning of October 26, 2026, a live GO IAQS Score assessment scored 23 active sensors:
- 21 Rooms Rated “A” (Good)
- 2 Rooms Rated “B” (Moderate)
- Room 413 – Payload too Large: Driven by a CO2 reading of 891 ppm
- Hardware Area: Driven by a rolling radon level of 124 Bq/m3
- 0 Rooms Rated “Z” (Unhealthy)
Under the GO IAQS framework, a Band B designation serves as a direct, intuitive prompt for action: ventilate the room, inspect air supply, or reduce internal source generation before air quality degrades further.

Clear Data Leads to Action
By implementing GO IAQS at its Oslo headquarters, Airthings showed that indoor environmental health does not require guesswork. Pairing reliable sensor networks with standardized performance tiers allows facility leaders, human resources, and building operators to speak the same language, shifting indoor air quality management from passive monitoring to precise, continuous optimization.
Methodology & Data Notes
- Data Sources & Scope: Data collected from 23 commercial Airthings monitoring devices installed across Airthings HQ in Oslo, Norway, spanning September 26 to October 25, 2026 (Europe/Oslo time zone; 20 business days).
- Occupied Hours: Calculations are restricted strictly to building operating hours: Monday through Friday, 07:00 to 17:00. Hours where devices reported no data were excluded from calculations rather than counted as healthy. Software and Product Area (100 hours) and its Space Radon sensor (30 hours) reported partial data.
- Measurement Parameters: Sensors evaluated three of the seven GO IAQS pollutants: CO2 (instantaneous limit: 800 ppm), radon (rolling average limit: 100 Bq/m3), and PM2.5 1-hour average limit: 15 μg/m3, deployed in Lounge and Nitrogen). Exceedances reflect the GO IAQS Ultimate standard thresholds.
Find the complete report here and visit Airthings at www.airthings.com